Sam4s ER-380 Specifications Page 89

  • Download
  • Add to my manuals
  • Print
  • Page
    / 193
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 88
ER-380 / ER-380M Electronic Cash Register AU Service Mode Programming 79
Memory Allocation
NB. This will clear the Memory!
Program 60 - Memory Allocation Programming
1. Turn the control lock to the S-Mode.
2. To Allocate Memory, enter 6 0, and then press the SBTL key.
0 SBTL 6
3. Refer to the chart below. Enter the index number and press the X/TIME key.
X X/TIME
X MEMORY ITEM
1
PLU
2
CLERK
3
GROUP
4
CHECK#
5
SOFT CHECK LINE
6
CHECK TYPE : Hard (1), Soft (0)
7
PRICE LEVEL
8
MIX AND MATCH
9
ELECTRONIC JOURNAL
4. Enter the Number to allocate for the Memory Item and Press CASH key.
See the example data table below
N CASH
MEMORY ITEM N
PLU
300 (Max.5000)
CLERK
15 (Max. 99)
GROUP
20 (Max. 99)
CHECK #
15 (Max. 500)
SOFT CHECK LINE
30 (Max. 100)
CHECK TYPE
0(Soft Check), 1(Hard Check)
PRICE LEVEL
1 (Max. 2)
MIX AND MATCH
10 (Max. 100)
ELECTRONIC JOURNAL
3000(Max. 15000)
ÚDefault values have been highlighted in bold print
5. If you want to finish memory allocation, press CASH key again with no numeric key input.
If you want to allocate another memory area, repeat step 3 and 4.
CASH
Page view 88