84 Service Mode Programming ER-380 / ER-380M Electronic Cash Register AU
RS232C Serial Port #1 Communication Options
You must define the device that is attached to the RS-232C communications port, and the options for
the device. The Default is Comm1 is set to PC Polling
Program 80 - RS232C Serial Port #1 Communication Options
1. Turn the control lock to the S-Mode.
2. Enter 8 0 and press the SBTL key.
3. Refer to the chart RS-232C option chart that follows and enter the number of the address
you wish to program and press the X/TIME key.
4. Enter the value that represents your selection and press the CASH key.
5. Repeat from step 2 for any additional options you wish to program.
6. Press CASH to exit the program
XTIME
Repeat for another Index
N1 SBTL 0 8 CASH N2 CASH
N1 OPTION N2 VALUE
0 9600 BPS
1 1200 BPS
2 2400 BPS
3 4800 BPS
1
Baud Rate
4 19200 BPS
0 NONE
1 ODD
2
Parity
2 EVEN
0 8 BITS 3
Data Bits
1 7 BITS
0 1 BIT 4
Stop Bits
1 2 BIT
0 NONE
1 PC
2 SCALE
3 RJ* / CCTV (EPROM v2.3)
4 RECEIPT PRINTER
6 SCANNER
7 COIN
8 EFT
5
Device Function
(Port #1 preset for 1 (PC) on
both ER-380 and ER-380M;
Port #2 preset for 0 (NONE)
on ER-380M)
9 POLE
6
Initial Feeding Line KP 0 - 20
0