System Option Table
Address SYSTEM OPTION VALUE = SUM
Beeper is active? Yes = 0
No = 1
1
Clerk operation is real clerk key?
Yes = 2
No = 0
Direct entry = 0
2
Clerk sign on method is:
Code entry = 1
Pop-up = 1
3
Clerks are:
Stay down = 0
Enforce closed drawer for register operation? Yes = 0
No = 1
4
Open drawer alarm is active? Yes = 2
No = 0
5
The number of seconds before the open drawer
warning tone sounds (default is 30 seconds).
1-99
Allow the post tender function? Yes = 1
No = 0
Drawer is opened on post tender? Yes = 0
No = 2
6
Allow multiple receipts? Yes = 4
No = 0
Cash declaration is compulsory before reports
may be taken?
Yes = 1
No = 0
7
Allow negative balance sales in the X control
lock position only?
Yes = 2
No = 0
Allow zero balance sales in the X control lock
position only?
Yes = 1
No = 0
8
Consecutive number is reset after a financial
report?
Yes = 2
No = 0
Grand total is reset after a Z Financial report? Yes = 1
No = 0
Cash drawer will open when reports are run? Yes = 0
No = 2
9
Open drawer during training mode? Yes = 0
No = 4
10
Decimal place: (0,1,2,3) default=2 0-3
MMDDYY = 0(default)
DDMMYY = 1
11
Date format is:
YYMMDD = 2
Page view 108